ADMIRAL – Status display

Emitter – All models

Admiral emettitore
1 Yellow LED 2 Red LED 3 Green LED Display Meaning
⊗ ⊗ ⊗ 8 System power-on – Initial TEST
⊗ ⊗ ⊗ L / H TEST condition
⊗ ⊗ ⊗ L GUARD condition. Low range
⊗ ⊗ ⊗ H GUARD condition. High range
⊗ ⊗ ⊗ Code FAIL condition – The type of fault is identified by the code number on display. See next “Fail condition tablel”

Fail condition

Display code Meaning
F – P Range selection incorrect or modified
F – A Internal error (add-on board)
F – 3 Internal error (master board)
F – 4 Internal error

 

Receiver – ADMIRAL AD

Admiral AX BK ricevitore
1 Yellow LED 2 Red LED 3 Green LED Display Meaning
⊗ ⊗ ⊗ 8 System power-on – Initial TEST
⊗ ⊗ ⊗

–

BREAK condition
⊗ ⊗ ⊗ – Received beam signal intensity is weak
⊗ ⊗ ⊗ – GUARD condition
⊗ ⊗ ⊗ Code FAIL condition – The type of fault is identified by the code number on display. See next “Fail condition table”

Fail condition

Display code Meaning
O Overcurrent on one or both outputs (OSSD)
F – 1 Detection of a hazardous interfering Emitter condition. The Receiver is able to receive the beams emitted by two different Emitters at the same time.
(This fault is displayed for at least 30 seconds)
F – 2 Connection of load between static outputs (OSSD) and the positive power supply line (+ 24 Vdc)
F – 4 Internal failure relating to the microcontroller boards
F – 5 Erroneous connection of static outputs (OSSD)
F – 6 Probable short circuit between the two outputs (OSSD)

 

Receiver – ADMIRAL AX

Admiral AX BK ricevitore
1 Yellow LED 2 Red LED 3 Green LED Display Meaning
⊗ ⊗ ⊗ 8 System power-on – Initial TEST
⊗ ⊗ ⊗ C C displayed for 10 sec. – Manual restart with feedback disabled
⊗ ⊗ ⊗ C C displayed for 10 sec. – Manual restart with feedback enabled
⊗ ⊗ ⊗ C C displayed for 10 sec. – Automatic restart with feedback disabled
⊗ ⊗ ⊗ C C displayed for 10 sec. – Automatic restart with feedback enabled
⊗ ⊗ ⊗

–

BREAK condition
⊗ ⊗ ⊗

D

BREAK condition with weak signal
⊗ ⊗ ⊗

–

CLEAR condition. Waiting for restart
⊗ ⊗ ⊗

D

CLEAR condition with weak signal
⊗ Blinking ⊗ ⊗

–

Master in CLEAR, Slave in BREAK conditions (Master Models only)
⊗ Blinking  ⊗ ⊗

D

Master in CLEAR, Slave in BREAK conditions with weak signal.(Master Models only)
⊗ ⊗ ⊗ – GUARD condition
⊗ ⊗ ⊗ D GUARD condition with weak signal
⊗ ⊗ ⊗   Receiver initialization
⊗ ⊗ ⊗ Code FAIL condition – The type of fault is identified by the code number on display. See next “Fail condition table”

 

Fail condition

Display code Meaning
O Overload of the OSSD static outputs
F – C Customer configuration rejected
F – 2 OSSD erroneously connectedt o 24VDC
F – E External Feedback contactors missed
F – 3 Internal error
F – 4
F – A
F – 6 OSSD1 – OSSD2 short–circuit
F – 0 Overload of the OSSD static outputs (only for MASTER models)
F – 5 OSSD static outputs error
F – I Interfering dangerous Emitter detected.
The receiver is able to receive simultaneously the beams from two
different Emitters
(30 sec)
F – U SLAVE connections incorrect (only for MASTER models)
F – H User configuration changed without system restart (only for MASTER models)

 

Receiver – ADMIRAL AX BK

Admiral AX BK ricevitore
1 Yellow LED 2 Red LED 3 Green LED Display Meaning
⊗ ⊗ ⊗ 8 System power-on – Initial TEST
⊗ ⊗ ⊗ C C displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A1
⊗ ⊗ ⊗ C C displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A2
⊗ Blinking ⊗ ⊗ C C displayed for 10 sec. – Blanking S.O.P.O. (Without Object Presence Obligation) Mode A3
⊗ ⊗ ⊗ C C displayed for 10 sec. – Blanking C.O.P.O. (With Object Presence Obligation) Mode B1
⊗ ⊗ ⊗ C C displayed for 10 sec. – Blanking C.O.P.O. (With Object Presence Obligation) Mode B2
⊗ ⊗ ⊗

–

BREAK condition
⊗ ⊗ ⊗

D

BREAK condition with weak signal
⊗  ⊗  ⊗ 

B

BREAK condition in case of Mode B1/B2 blanking
⊗ ⊗  ⊗ 

B

BREAK condition in case of Mode B1/B2 blanking with weak signal
⊗ ⊗ ⊗

J

Master in CLEAR, Slave in BREAK conditions (Master Models only)
⊗ ⊗ ⊗

J

Master in CLEAR, Slave in BREAK conditions with weak signal.(Master Models only)
⊗ ⊗ ⊗ – GUARD condition
⊗ ⊗ ⊗ – GUARD condition with weak signal
⊗ ⊗ ⊗ R Active blanking conditions
⊗ ⊗ ⊗ R Active blanking conditions with weak signal
⊗ ⊗ ⊗   Receiver initialization
⊗ ⊗ ⊗ Code FAIL condition – The type of fault is identified by the code number on display. See previous “Fail condition table”