SAFEGATE – Status display

Emitter – All models

Safegate emettitore
Three colour LED Meaning
⊗ System power-on – Initial TEST
⊗ Blinking

FAIL condition – The type of fault is identified by the number of flashes – See next “Fail condition table”

⊗ TEST condition
⊗ Normal operating condition

Fail condition

Three colour LED Nr Flashes Meaning
⊗ 2 consecutive RANGE0 / RANGE1 wrong wiring
⊗ 3/4 consecutive Internal falilure
⊗ 5 consecutive SYNC wrong wiring

 

Receiver – All models with muting functions

Safegate ricevitore con funzione di Muting
1 PRG LED 2 COM/WEAK LED 3 CLR LED 4 Two colour LED 5 MUT LED 6 OVR LED 7 S1 LED 8 S2 LED 9 S3 LED 10 S4 LED Meaning
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Curtain programmed via USB
⊗ ⊗ ⊗  ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Communication with active PC
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Weak signal (14 mm and long range models only)
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Curtain awaiting RESTART (clear gate)
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Normal operation
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Occupied gate
⊗ ⊗ ⊗ ⊗ Blinking ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ FAIL condition – The type of fault is identified by the number of flashes – See next “Fail condition table”
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Muting active
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Override active
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Blinking  ⊗ ⊗ ⊗ ⊗ Override request
⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Muting sensors interrupted
⊗ Blinking ⊗ Blinking ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ No barrier programmation
⊗ Blinking ⊗ Blinking ⊗ ⊗ Blinking  ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Detected double programmation
(hardware and software)

 

Fail condition

3 CLR LED Nr. flashes  4 Two colour LED Nr. fleshes 5 MUT LED Nr. fleshes 6 OVR LED Nr. fleshes 7 S1 LED 8 S2 LED 9 S3 LED 10 S4 LED Meaning
⊗ ⊗ 2 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Configuration error SEL_A/SEL_B/EDM
⊗ ⊗ 2 ⊗ ⊗ ⊗ 2 ⊗ 2 ⊗ ⊗ Inconsistency between red and blue connector
selection for S2 wiring and the physical wiring of S2
⊗ ⊗ 3 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Wrong EDM configuration
⊗ 3 ⊗ 3 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ EDM feedback failure
⊗ ⊗ 3 ⊗ 3 ⊗ ⊗ ⊗ ⊗ ⊗ STATUS input failure
⊗ ⊗ 3 ⊗ ⊗ 3 ⊗ ⊗ ⊗ ⊗ OVERRIDE_1 / OVERRIDE_1 input failure
⊗ ⊗ 3 ⊗ ⊗ ⊗ 3 ⊗ 3 ⊗ 3 ⊗ 3 SENSOR input failure
⊗ 3 ⊗ 3 ⊗ 3 ⊗ 3 ⊗ ⊗ ⊗ ⊗ MUTING LAMP FAILURE
⊗ ⊗ 4 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ OSSD1 / OSSD2 error
⊗ ⊗ 5 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ MAIN CARD ERROR
⊗ 5 ⊗ 5 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ BASE SHEET (EEPROM) error
⊗ ⊗ 5 ⊗ ⊗ 5 ⊗ ⊗ ⊗ ⊗ MAIN CARD ERROR
⊗ ⊗ 6 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ MAIN CARD (Microcontroller) error
⊗ 6  ⊗ 6 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ GENERIC DEFAULT BOARD ERROR
⊗ ⊗ 6 ⊗ 6 ⊗ ⊗ ⊗ ⊗ ⊗ Beam error
⊗ ⊗ 6 ⊗ ⊗ 6 ⊗ ⊗ ⊗ ⊗ 24VDC power supply overload
⊗ ⊗ 6 ⊗ 6 ⊗ 6 ⊗ ⊗ ⊗ ⊗ LAMP/STATUS over current
⊗ ⊗ 7 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Receiving beams failure
⊗ ⊗ 8 ⊗ ⊗ ⊗ ⊗ ⊗ ⊗ Interfering Emitter Detected

 

 

Receiver – All models without Muting functions

Safegate ricevitore con funzione di Muting

 

2. WEAK LED 3. CLR LED 4. Two colour LED Meaning
⊗ ⊗ ⊗ Weak signal (14 mm and long range models only)
⊗ ⊗ ⊗ Curtain awaiting RESTART (clear gate)
⊗ ⊗ ⊗ Normal operation
⊗ ⊗ ⊗ Occupied gate
⊗ ⊗ ⊗ Blinking FAIL condition – The type of fault is identified by the number of flashes – See previous “Fail condition table”