{"id":40839,"date":"2021-07-27T12:19:34","date_gmt":"2021-07-27T10:19:34","guid":{"rendered":"https:\/\/www.reersafety.com\/?page_id=40839"},"modified":"2023-03-03T10:50:00","modified_gmt":"2023-03-03T09:50:00","slug":"calcolo-del-sottosistema-pfh","status":"publish","type":"page","link":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/","title":{"rendered":"PFH come parametro di riferimento per misurare l&#8217;integrit\u00e0 della sicurezza hardware del SCS"},"content":{"rendered":"\n<div class=\"row\"  id=\"row-1169901952\">\n\n\n\t<div id=\"col-533319184\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  <div id=\"page-header-389508853\" class=\"page-header-wrapper\">\n  <div class=\"page-title light simple-title\">\n\n    \n    <div class=\"page-title-inner container align-center flex-row medium-flex-wrap row-reverse\" >\n            <div class=\"title-content flex-col flex-left text-left medium-text-center\">\n        <div class=\"title-breadcrumbs pb-half pt-half\"><nav class=\"woocommerce-breadcrumb breadcrumbs uppercase\">Home<\/nav><\/div>      <\/div>\n    <\/div>\n\n       <\/div>\n    <\/div>\n  \n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-45928372\">\n\n\n\t<div id=\"col-1360936330\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"row\"  id=\"row-1315379790\">\n\n\n\t<div id=\"col-1792301157\" class=\"col small-12 large-12\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-4139918861\" class=\"text cutom-ul\">\n\t\t\n\n<h2>PFH come parametro di riferimento per misurare l&#8217;integrit\u00e0 della sicurezza hardware del SCS<\/h2>\n<p>Il parametro utilizzato per definire le prestazioni di sicurezza del SIL (Safety Integrity Level) \u00e8 la probabilit\u00e0 di guasto pericoloso\/ora (PFH<sub>d<\/sub>). Pi\u00f9 alto \u00e8 il SIL, meno \u00e8 probabile che SCS non esegua la funzione di sicurezza richiesta.<\/p>\n<p>Il SIL deve essere definito per ciascuna funzione relativa alla sicurezza risultante dall&#8217;analisi dei rischi.<\/p>\n<p>La tabella 3 della norma fornisce una corrispondenza tra SIL e PFH.<\/p>\n<table style=\"height: 106px; width: 20%; border-collapse: collapse;\">\n<tbody>\n<tr style=\"height: 22px;\">\n<td style=\"width: 42.105%; height: 22px; text-align: center;\" colspan=\"2\"><strong>Limiti del SIL e valori di PFH<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 10.7422%; height: 21px;\">SIL<\/td>\n<td style=\"width: 31.3628%; height: 21px;\">Valori PFH<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 10.7422%; height: 21px;\">1<\/td>\n<td style=\"width: 31.3628%; height: 21px;\">&lt; 10<sup>-5<\/sup><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 10.7422%; height: 21px;\">2<\/td>\n<td style=\"width: 31.3628%; height: 21px;\">&lt; 10<sup>-6<\/sup><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 10.7422%; height: 21px;\">3<\/td>\n<td style=\"width: 31.3628%; height: 21px;\">&lt; 10<sup>-7<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tabella 3 &#8211; Limiti del SIL e valori PFH<\/p>\n<h3>Determinazione del PFH del SCS<\/h3>\n<p>Il PFH di un SCS \u00e8 la somma dei singoli valori del PFH di tutti i sottosistemi che partecipano alla realizzazione del SCS e include la probabilit\u00e0 di errori di trasmissione pericolosi (PTE) per qualsiasi comunicazione di dati digitali.<\/p>\n<p style=\"text-align: center;\"><span style=\"font-size: 130%; color: #333399;\">PFH scs = PFH sottosistema 1 + &#8230; + PFH sottosistema n +PTE<\/span><\/p>\n<p style=\"text-align: left;\">I sottosistemi di cablaggio hardware fanno parte dell&#8217;integrit\u00e0 sistematica e possibili guasti pericolosi nel cablaggio possono essere rilevati dalla diagnostica in linea.<\/p>\n<h3 style=\"text-align: left;\">Determinazione del SIL del SCS<\/h3>\n<p style=\"text-align: left;\">Dopo aver derivato il PFH dell&#8217;SCS, il SIL risultante \u00e8 ricavato dalla Tabella 3. Ne deriva che il SIL massimo \u00e8 limitato dalla somma dei valori PFH di tutti i sottosistemi.<\/p>\n<p style=\"text-align: left;\">Il SIL dell&#8217;SCS pu\u00f2 essere solo uguale o inferiore al SIL pi\u00f9 basso di uno qualsiasi dei sottosistemi partecipanti alla realizzazione dell&#8217;SCS. Tuttavia, i valori PFH dei singoli sottosistemi non sono soggetti a restrinzioni (ad esempio un sottosistema SIL 2 pu\u00f2 avere un PFH inferiore a 10<sup>-7<\/sup>).<\/p>\n\t\t\n<style>\n#text-4139918861 {\n  color: rgb(0,0,0);\n}\n#text-4139918861 > * {\n  color: rgb(0,0,0);\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\" rel=\"\">\n\n<div class=\"accordion-item\"><a href=\"#\" class=\"accordion-title plain\"><button class=\"toggle\"><i class=\"icon-angle-down\"><\/i><\/button><span>Esempio<\/span><\/a><div class=\"accordion-inner\">\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_564341099\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 200px;\">\n\t\t\t<img width=\"800\" height=\"131\" src=\"https:\/\/reer-stage.reersafety.com\/wp-content\/uploads\/2022\/04\/IT_SIL-of-SCS-example.png\" class=\"attachment-large size-large\" alt=\"Esempio di SIL\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/reer-stage.reersafety.com\/wp-content\/uploads\/2022\/04\/IT_SIL-of-SCS-example.png 800w, https:\/\/reer-stage.reersafety.com\/wp-content\/uploads\/2022\/04\/IT_SIL-of-SCS-example-300x49.png 300w, https:\/\/reer-stage.reersafety.com\/wp-content\/uploads\/2022\/04\/IT_SIL-of-SCS-example-768x126.png 768w, https:\/\/reer-stage.reersafety.com\/wp-content\/uploads\/2022\/04\/IT_SIL-of-SCS-example-510x84.png 510w\" sizes=\"(max-width: 800px) 100vw, 800px\" title=\"Esempio di SIL\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_564341099 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n<p style=\"text-align: center;\"><span style=\"font-size: 130%; color: #333399;\">PFH<sub>CS<\/sub> = 1,5&#215;10<sup>-8<\/sup> + 2&#215;10<sup>-9<\/sup> + 4&#215;10<sup>-8<\/sup> = <span style=\"color: #d83131;\">5,7 x 10<sup>-8<\/sup><\/span><\/span><\/p>\n<table style=\"border-collapse: collapse; width: 48.9603%; height: 105px;\">\n<tbody>\n<tr style=\"height: 21px;\">\n<td style=\"width: 48.7713%; height: 21px;\" colspan=\"2\">Limiti del SIL e valori di PFH<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 17.9584%; height: 21px;\">SIL<\/td>\n<td style=\"width: 30.8129%; height: 21px;\">Valori PFH<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 17.9584%; height: 21px;\">1<\/td>\n<td style=\"width: 30.8129%; height: 21px;\">&lt; 10<sup>-5<\/sup><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 17.9584%; height: 21px;\">2<\/td>\n<td style=\"width: 30.8129%; height: 21px;\">&lt; 10<sup>-6<\/sup><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 17.9584%; height: 21px;\">3<\/td>\n<td style=\"width: 30.8129%; height: 21px;\"><span style=\"color: #d83131;\">&lt; 10<sup>-7<\/sup><\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ne deriva che il SIL di questo SCS, nonostante il valore PFH complessivo sia adatto per un SIL 3, \u00e8 limitato a SIL 2, essendo SIL 2 il SIL inferiore dei tre sottosistemi.<\/p>\n<p>Inoltre, l&#8217;integrit\u00e0 di sicurezza dell&#8217;SCS \u00e8 limitata anche dalle capacit\u00e0 sistematiche (ad esempio influenze ambientali, EMC e principio di rilevamento).<\/p>\n\n<\/div><\/div>\n\n<\/div>\n<h3>Requisiti per l&#8217;integrit\u00e0 sistematica della sicurezza<\/h3>\n<p>Il valore di PFH \u00e8 solo uno dei parametri che contribuiscono all&#8217;assegnazione del SIL.<\/p>\n<p>Per richiedere un SIL \u00e8 inoltre necessario dimostrare che tutti i requisiti relativi a:<\/p>\n<ul>\n<li>Per evitare i guasti hardware sistematici<\/li>\n<li>Il controllo dei guasti sistematici<\/li>\n<li>L&#8217;utilizzo di componenti robusti e affidabili (conformi alle norme di prodotto, ove disponibili)<\/li>\n<li>Le condizioni ambientali in cui dovr\u00e0 operare il sistema di sicurezza.<\/li>\n<\/ul>\n<p>Sono stati presi in considerazione e rispettati e, qualora fosse necessario scrivere del codice software, aver adottato tutti gli aspetti organizzativi e progettuali rilevanti per il SIL obiettivo.<\/p>\n<h4>Misure di sicurezza rispetto ai fenomeni elettromagnetici<\/h4>\n<p>L&#8217;SCS non deve essere influenzato da interferenze elettromagnetiche al punto da disturbare o rendere inefficace la funzione di sicurezza in un modo che potrebbe comportare un rischio inaccettabile.<\/p>\n<p>\u00c8 pertanto obbligatoria una prestazione adeguata rispetto ai disturbi elettromagnetici.<\/p>\n<p>Se disponibili, devono essere utilizzati solo dispositivi o apparecchiature elettriche e\/o elettroniche che soddisfano i requisiti della relativa norma di prodotto in materia di immunit\u00e0 ai fenomeni elettromagnetici. Esempi di tali standard di prodotto sono IEC 61326-3-1, IEC 61800-5-2, IEC 61496-1, IEC 60947-5-3 (stadio CD).<\/p>\n<p>Se non esiste una norma di prodotto dedicata alle influenze elettromagnetiche sugli aspetti di sicurezza funzionale, <br>dovrebbe essere applicata la norma generica IEC 61000-6-7:2014. Deve essere effettuata un&#8217;analisi completa della sicurezza relativa agli effetti dei disturbi elettromagnetici sull&#8217;SCS per ricavare i limiti di immunit\u00e0 richiesti per il SIL necessario.<\/p>\n<p>Per i sottosistemi pre-progettati secondo questo standard, i disturbi elettromagnetici prevedibili nell&#8217;ambiente reale dell&#8217;apparecchiatura dovrebbero essere considerate nell&#8217;SRS. I requisiti di immunit\u00e0 dovrebbero essere basati sulla norma generica IEC 61000-6-7:2014 se per il sottosistema non esiste una famiglia di prodotti dedicata o una norma di prodotto pertinente che affronti le influenze elettromagnetiche sulla sicurezza funzionale. Per i sottosistemi pre-progettati progettati secondo PL a o PL b di ISO 13849-1 seguire lo standard EMI applicabile \u00e8 IEC 61000-6-2:2014.<\/p>\n<p>Per l&#8217;integrazione di SCS nell&#8217;equipaggiamento elettrico della macchina devono essere applicate le misure EMI secondo l&#8217;allegato H della IEC 60204-1. In particolare:<\/p>\n<ul>\n<li>Evitare grandi circuiti conduttivi, non installare diversi sistemi di cablaggio elettrico in percorsi comuni (ad es. cavi di alimentazione, comunicazione, controllo e segnale)<\/li>\n<li>Utilizzare il filtro RF e la protezione da sovratensione e transitoria per i segnali di ingresso\/uscita relativi alla sicurezza<\/li>\n<li>Se applicabile, cavi schermati e con messa a terra per motori o filtro sinusoidale tra motore e inverter o misure equivalenti.<\/li>\n<\/ul>\n<div class=\"is-divider divider clearfix\" style=\"max-width:100px;\"><\/div>\n\n<div class=\"row\"  id=\"row-1107899622\">\n\n\n\t<div id=\"col-2022095140\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"ux-menu stack stack-col justify-start ux-menu--divider-solid\">\n\t\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/reer-stage.reersafety.com\/en\/academy\/industrial-safety-guide\/iec-62061-safety-of-machinery\/\"  >\n\t\t\t<i class=\"ux-menu-link__icon text-center icon-angle-left\" ><\/i>\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tIEC 62061 Sicurezza del macchinario\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-185539090\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1099620521\" class=\"col medium-4 small-12 large-4\"  >\n\t\t<div class=\"col-inner text-right\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"ux-menu stack stack-col justify-start ux-menu--divider-solid\">\n\t\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/reer-stage.reersafety.com\/en\/academy\/industrial-safety-guide\/iec-62061-safety-of-machinery\/safety-related-application-software\/\"  >\n\t\t\t<i class=\"ux-menu-link__icon text-center icon-angle-right\" ><\/i>\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tSoftware applicativo relativo alla sicurezza\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t<\/div>\n\n\t\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":0,"parent":54023,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Il parametro PFH - ReeR Safety<\/title>\n<meta name=\"description\" content=\"PFH come parametro di riferimento per misurare l&#039;integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Il parametro PFH - ReeR Safety\" \/>\n<meta property=\"og:description\" content=\"PFH come parametro di riferimento per misurare l&#039;integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/\" \/>\n<meta property=\"og:site_name\" content=\"ReeR\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-03T09:50:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/\",\"url\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/\",\"name\":\"Il parametro PFH - ReeR Safety\",\"isPartOf\":{\"@id\":\"https:\/\/reer-stage.reersafety.com\/it\/#website\"},\"datePublished\":\"2021-07-27T10:19:34+00:00\",\"dateModified\":\"2023-03-03T09:50:00+00:00\",\"description\":\"PFH come parametro di riferimento per misurare l'integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!\",\"breadcrumb\":{\"@id\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/reer-stage.reersafety.com\/it\/homepage\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Academy\",\"item\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Guida alla sicurezza\",\"item\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"IEC 62061 Sicurezza del macchinario\",\"item\":\"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"PFH come parametro di riferimento per misurare l&#8217;integrit\u00e0 della sicurezza hardware del SCS\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/reer-stage.reersafety.com\/it\/#website\",\"url\":\"https:\/\/reer-stage.reersafety.com\/it\/\",\"name\":\"ReeR\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/reer-stage.reersafety.com\/it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"it-IT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Il parametro PFH - ReeR Safety","description":"PFH come parametro di riferimento per misurare l'integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"it_IT","og_type":"article","og_title":"Il parametro PFH - ReeR Safety","og_description":"PFH come parametro di riferimento per misurare l'integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!","og_url":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/","og_site_name":"ReeR","article_modified_time":"2023-03-03T09:50:00+00:00","twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/","url":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/","name":"Il parametro PFH - ReeR Safety","isPartOf":{"@id":"https:\/\/reer-stage.reersafety.com\/it\/#website"},"datePublished":"2021-07-27T10:19:34+00:00","dateModified":"2023-03-03T09:50:00+00:00","description":"PFH come parametro di riferimento per misurare l'integrit\u00e0 della sicurezza hardware del SCS. Visita il sito ReeR Safety!","breadcrumb":{"@id":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/calcolo-del-sottosistema-pfh\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/reer-stage.reersafety.com\/it\/homepage\/"},{"@type":"ListItem","position":2,"name":"Academy","item":"https:\/\/reer-stage.reersafety.com\/it\/academy\/"},{"@type":"ListItem","position":3,"name":"Guida alla sicurezza","item":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/"},{"@type":"ListItem","position":4,"name":"IEC 62061 Sicurezza del macchinario","item":"https:\/\/reer-stage.reersafety.com\/it\/academy\/guida-alla-sicurezza-industriale\/iec-62061-sicurezza-del-macchinario\/"},{"@type":"ListItem","position":5,"name":"PFH come parametro di riferimento per misurare l&#8217;integrit\u00e0 della sicurezza hardware del SCS"}]},{"@type":"WebSite","@id":"https:\/\/reer-stage.reersafety.com\/it\/#website","url":"https:\/\/reer-stage.reersafety.com\/it\/","name":"ReeR","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/reer-stage.reersafety.com\/it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"it-IT"}]}},"_links":{"self":[{"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/pages\/40839"}],"collection":[{"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/comments?post=40839"}],"version-history":[{"count":16,"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/pages\/40839\/revisions"}],"predecessor-version":[{"id":66286,"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/pages\/40839\/revisions\/66286"}],"up":[{"embeddable":true,"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/pages\/54023"}],"wp:attachment":[{"href":"https:\/\/reer-stage.reersafety.com\/it\/wp-json\/wp\/v2\/media?parent=40839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}