SAFEGATE – Status display

Emitter – All models

Three colour LED Meaning
System power-on – Initial TEST
Blinking

FAIL condition – The type of fault is identified by the number of flashes – See next “Fail condition table”

TEST condition
Normal operating condition

Fail condition

Three colour LED Nr Flashes Meaning
2 consecutive RANGE0 / RANGE1 wrong wiring
3/4 consecutive Internal falilure
5 consecutive SYNC wrong wiring

 

Receiver – All models with muting functions

1 PRG LED 2 COM/WEAK LED 3 CLR LED 4 Two colour LED 5 MUT LED 6 OVR LED 7 S1 LED 8 S2 LED 9 S3 LED 10 S4 LED Meaning
Curtain programmed via USB
  Communication with active PC
Weak signal (14 mm and long range models only)
Curtain awaiting RESTART (clear gate)
Normal operation
Occupied gate
Blinking FAIL condition – The type of fault is identified by the number of flashes – See next “Fail condition table”
Muting active
Override active
Blinking  Override request
Muting sensors interrupted
Blinking Blinking No barrier programmation
Blinking Blinking Blinking  Detected double programmation
(hardware and software)

 

Fail condition

3 CLR LED Nr. flashes  4 Two colour LED Nr. fleshes 5 MUT LED Nr. fleshes 6 OVR LED Nr. fleshes 7 S1 LED 8 S2 LED 9 S3 LED 10 S4 LED Meaning
2 Configuration error SEL_A/SEL_B/EDM
2  2  2 Inconsistency between red and blue connector
selection for S2 wiring and the physical wiring of S2
3 Wrong EDM configuration
 3 3 EDM feedback failure
3 3 STATUS input failure
3 3 OVERRIDE_1 / OVERRIDE_1 input failure
3 3 3 3 3 SENSOR input failure
3 3 3 3 MUTING LAMP FAILURE
4 OSSD1 / OSSD2 error
5 MAIN CARD ERROR
5 5 BASE SHEET (EEPROM) error
5 5 MAIN CARD ERROR
6 MAIN CARD (Microcontroller) error
6   6 GENERIC DEFAULT BOARD ERROR
6 6 Beam error
6 6 24VDC power supply overload
6 6 6 LAMP/STATUS over current
7 Receiving beams failure
8 Interfering Emitter Detected

 

 

Receiver – All models without Muting functions

 

2. WEAK LED 3. CLR LED 4. Two colour LED Meaning
Weak signal (14 mm and long range models only)
Curtain awaiting RESTART (clear gate)
Normal operation
Occupied gate
Blinking FAIL condition – The type of fault is identified by the number of flashes – See previous “Fail condition table”