EOS – Status display

Emitter – All models

EOS emitter
Three colour LED Meaning
⊗ System power-on – Initial TEST
⊗ 2 Flashes System power-on – HIGH working range selected
⊗ Blinking

FAIL condition – The type of fault is identified by the number of flashes – See next „Fail condition table“

⊗ TEST condition
⊗ Normal operating condition

Fail condition

Three colour LED Nr Flashes Meaning
⊗ 2 consecutive Irregular connection of pins 2 and 4
⊗ 3/4 consecutive Internal falilure
⊗ 5 consecutive Master and slave not compatible
⊗ Continue Awaiting communication Master/Slave (only on Slave light curtains)
⊗ 2 consecutive Loss of Master/Slave communication (only on Master and Slave2 light curtain)

 

Receiver – All models except EOS4 14 mm and H (range 20 m) versions

EOS receiver
1 Yellow LED 2 Two colour LED Meaning
⊗ ⊗ System power-on – Initial TEST
⊗ ⊗ BREAK condition
⊗ ⊗ CLEAR condition – EOS4 X (with integrated control functions) only
⊗ blinking ⊗ blinking  BREAK_K condition – EOS4 X (with integrated control functions) only
⊗ ⊗ GUARD condition
⊗ ⊗ blinking FAIL condition – The type of fault is identified by the number of flashes – See next „Fail condition table“
⊗ blinking ⊗ MASTER light curtain free; SLAVE light curtain(s) occupied

 

Fail condition

1 Yellow LED 2 Two colour LED Nr. Flashes Meaning
⊗ ⊗ 2 consecutive Incorrect configuration
⊗ ⊗ 3 consecutive Absence Feedback
⊗ ⊗ 4 consecutive Interfering emitter detected
⊗ ⊗  5 consecutive OSSD outputs error
⊗ ⊗  6/7 consecutive Internal failure
⊗ ⊗ 8 consecutive Incorrect Master/Slave connections (only on Master and Slave light curtains)

 

Receiver – EOS4 14 mm and H (range 20 m) versions

EOS H version receiver
1 Two colour LED 2 Two colour LED Meaning
⊗ ⊗ System power-on – Initial TEST
⊗ ⊗ BREAK condition
⊗ ⊗ CLEAR condition – EOS4 X (with integrated control functions) only
⊗ blinking ⊗ blinking  BREAK_K condition – EOS4 X (with integrated control functions) only
⊗ ⊗ GUARD condition
⊗ ⊗ blinking FAIL condition – The type of fault is identified by the number of flashes – See previous „Fail condition table“
⊗ ⊗ GUARD condition with weak signal
⊗⊗ alterneting ⊗ CLEAR condition with weak signal
⊗ ⊗ BREAK condition with weak signal
⊗⊗ alterneting bilinking ⊗ blinking BREAK_K condition with weak signal – EOS4 X (with integrated control functions) only